DC TC Fault Flowchart v1.3
DC TC FAULT (SOWC) FLOWCHART v1.3
THE FAILURE IS NOT A WSF. FOLLOW WSF TEST PLAN IF PROVEN TO BE A GENUINE WSF. DO NOT FOLLOW THIS GUIDE.
Main Decision
CAN SIGNALLER CLEAR SIGNAL OVER THE FAILED TRACK CIRCUIT?
YES → INDICATION ONLY FAULT
→ CHECK TKR CIRCUIT IN SIGNALBOX
NO → ACTUAL TRACK FAULT OR TPR FAULT
→ GO TO FEED END OR RELAY END
Feed End Checks
CHECK VOLTAGE ON RAILS (METER ON DC)
NO VOLTAGE → PARTIAL SHORT © → SEE PAGE A
PARTIAL/LOW → TC PROBABLY OK ©
HIGHER THAN NORMAL → TPR FAULT
FULL VOLTAGE → CHECK TR RELAY
Relay End Checks
CHECK TR RELAY IF AT LOC FIRST
CHECK VOLTAGE IF AT TRACK ENDS FIRST
FULL VOLTAGE →
  • CHECK TR CONTACTS
  • HIGH RESISTANCE → REPLACE RELAY ©
  • CONTACTS OK → CHECK NEXT TPR (TIPR)
PARTIAL VOLTAGE →
  • CHECK LOC & RAIL CONNECTIONS
  • IF ALL OK → TPR FAULT
CHECK TPR FEED FUSE
  • BLOWN → CHECK FOR BROKEN RAIL & CONNECTIONS
  • OK → CHECK CURRENT DRAWN & REPLACE FUSE
From Page One (A)
CHECK OUTPUT VOLTAGE ON TFU
  • OUTPUT OK
  • NO VOLTAGE →
    • WIRE OFF BETWEEN TFU & RAILS
    • TFU SUPPLY FUSE BLOWN
    • CHECK CURRENT & REPLACE FUSE
    • FULLY TEST TC ©
From Page One (B)
WALK TRACK, CHECK VOLTAGE EVERY 10m
  • CHECK PWAY INSULATIONS
  • CHECK IBJs
  • NOTHING FOUND → CONTINUE
  • INSULATIONS/IBJs FAIL →
    • TEST WITH K9
    • FOLLOW R.O.A CHECKS
    • PWAY TO REPAIR
From Page One (C)
TPR B50 FUSE BLOWN OR WIRE OFF
  • CHECK & RECTIFY
  • NO NEED TO TREAT TC AS FAILURE
From Page One (D)
FAULT IN TPR CIRCUIT IN FURTHER LOCS
  • CHECK ALL TPRs
  • CHECK 50v SUPPLY (45–55v)
  • IF HIGH → POSSIBLE DIS BETWEEN LOCS
  • RELAYS WON’T ENERGISE BELOW 37v
  • CHECK PREVIOUS RELAY CONTACTS
  • TEST CABLE CONTINUITY IF NEEDED
  • IF TC CLEARS → CONTINUE INVESTIGATION